Saptone FR Series membrane elements include 8-inch products and 4-inch ones, which are superior in reducing the organic pollution and inorganic fouling and advancing the cleaning recovery performance. Also, LongYuan has optimized the structure of membrane elements, adopted the widest inflow path in this field. This improves their anti-pollution performance and enables the elements to be cleaned effectively. Even under high pollution, the system can remain low pressure drop to reduce energy consumption.
Quantity: | |
---|---|
FR Series RO Membrane Elements
Saptone FR Series membrane elements include 8-inch products and 4-inch ones, which are superior in reducing the organic pollution and inorganic fouling and advancing the cleaning recovery performance. Also, LongYuan has optimized the structure of membrane elements, adopted the widest inflow path in this field. This improves their anti-pollution performance and enables the elements to be cleaned effectively. Even under high pollution, the system can remain low pressure drop to reduce energy consumption.
FR series are suitable for surface water, underground water, running water and municipal water with salinity of TDS<10000ppm. They are mainly applied for industrial water treatment including reuse of reclaimed water, refinery, papermaking, chemical filtration feed water system and surface water purification.
Specification and Main Performance of RO Membrane Elements
Type | Model | Performance | Structure Parameter | |||
Stable Rejection / % | Average permeate flux / gpd (m3/d) | Effective Membrane Area / ft2 | Flowpat Diameter / mil | Product Pipe Inside Diameter / mm | ||
FR Series | FR -8040-400/34 | 99.5 | 10000(37.9) | 400 | 34 | 28.7 |
FR -8040-365/36 | 99.5 | 9500(36.0) | 365 | 36 | 28.7 | |
FR -4040 | 99.5 | 2200( 8.3) | 90 | 34 | 19.0 | |
Testing Conditions: | ||||||
Testing Pressure | 225 psi(1.55 MPa) | |||||
Temperature of Testing Solution | 25 ℃ | |||||
Testing Concentration(NaCl) | 2000 mg/L | |||||
pH Value of Testing Solution | 7.5 | |||||
Recovery of Single Membrane Element | 20% | |||||
Operation Limits and Conditions: | ||||||
Max. Working Pressure | 600 psi(4.14 MPa) | |||||
Max. Feedwater Flow | 75 gpm(17 m3/h)(8040) | |||||
16 gpm(3.6 m3/h)(4040) | ||||||
Max. Inflow Temperature | 45 ℃ | |||||
Max. Inflow SDI15 | 5 | |||||
Residual Chlorine Concentration of Feedwater | <0.1 mg/L | |||||
pH Range of FeedwaterDuring Continuous Operation | 3~10 | |||||
pH Range of FeedwaterDuring Chemical Cleaning | 2~12 | |||||
Max Pressure Drop of Single Membrane Element | 15 psi(0.1 MPa) |